<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-31 13-51-51
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 59 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.5 kHz 23 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
10 kHz 73 kHz 10100 3,1683
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,3 dBr 7,64 dBr 8,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 13:51, 31.01.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (60 dBuV) Max at: 73 kHz MIN: 10 kHz % above 75 kHz: 3,1683 Acquired: 2025/01/31 13:50:48 Total samples: 10100 Equivalent time: 0:08:25 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 8,7 dBr MIN: 6,3 dBr AVE: 7,64 dBr % above 10,0 dBr: 0,0 Last value: 8,3 dBr (2025/01/31 13:50:47) Station: 96.90 MHz, signal: 4/5 (60 dBuV) 13:44 13:45 13:46 13:47 13:48 13:49 13:50 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality